Description and Specification for Lab Tenders
Astra Scientific Multi Heat Exchanger with data Acquisition.
The Offers basic experimental apparatus is used for studying of three
types of heat exchangers namely-concentric tube, shell and tube, and
plate-under parallel or counter flow conditions.
The unit consists of the three heat exchangers, and a service module.
The module comprises a hot water tank with a transfer pump and
instruments for monitoring and control. Selection of the heat exchanger
is simply done by opening a valve and changing from parallel to counter
flow is by switching two flexible hoses. The unit requires outside water
supply.
The microprocessor-based instrumentation is well protected in the
housing. The software consists of software for system operation and for
data acquisition and educational software. is connected to the PC via
USB.
FEATURES:
• Comparison of heat transfer for concentric tube, shell and tube, and plate heat exchanger.
• Demonstration of heat transfer under parallel or counter flow.
• Demonstration of batch type heat transfer for jacketed vessel.
• Determination heat transfer coefficient.
• Effects of flow rate and temperature difference.
• Useful for institutions, research laboratories & insulating powder manufactures
• Functions of the software: educational software, data acquisition, system operation
SPECIFICATION:
• Heat exchangers:
Concentric tube: 2 sections of stainless steel inner tube with clear acrylic casing.
Shell and tube: Stainless steel inner tubes with clear acrylic casing.
Plate: Stainless steel multiple plates.
• Service module consisting of
Hot water tank and pump.
Heater: 3000 W.
Temperatures: 14 ea.
Flow meters: Hot water and cold water.
Temperature control unit: 1 ea.
• Stainless steel jacketed vessel with coil and stirrer
• Vessel content
With a temperature sensor.
Jacket heat transfer area approximately 600 cm2
Coil heat transfer area approximately 350 cm2
Stirrer: 0- 500 rpm
• Measuring ranges
temperature: 2x 0…325°C
Heating power: 0…3000W
• Required for Operation
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase