Astra Scientific Computerized Thermal Conductivity of Liquid.
The heat transfer trainer offers basic experiments for targeted teaching
on the topic of heat conduction in fluids. Such teaching should discuss
the fundamental differences between gases and liquids.
Two cylinders form the main component of the experimental unit: an
electrically heated inner cylinder situated in a water-cooled outer
cylinder. There is a concentric annular gap between the two cylinders.
This annular gap is filled with the fluid being studied. The heat
conduction occurs from the inner cylinder, through the fluid to the
outer cylinder. The narrow annular gap prevents the formation of a
convective heat flux and allows a relatively large pass-through area
while at the same time providing a homogeneous temperature distribution.
The experimental unit is equipped with temperature sensors inside and
outside of the annular gap. Thermal conductivities for different fluids,
e.g. water, oil, air or carbon dioxide can be determined in
experiments.
The microprocessor-based instrumentation is well protected in the
housing. The software consists of a software for system operation and
for data acquisition and an educational software.
FEATURES:
• Steady heat conduction in gases and liquids:
o Determine the thermal resistance of fluids
o Determination of thermal conductivities k for different fluids at different temperatures
• Transient heat conduction in fluids:
o Interpret transient states during heating and cooling
o Introduction to transient heat conduction with the block capacity model
o Functions of the software: educational software, data acquisition, system operation
SPECIFICATION:
• Concentric annular gap between 2 cylinders containing the fluid being studied
• Inner cylinder, continuously electrically heated
• Water-cooled outer cylinder
• Heater
Heating power: 350W
Temperature limitation: 95°C
• Heat transfer area: 0,007439m2
• Annular gap
Height: 0,4mm
Average diameter: 29,6mm
• Inner cylinder
Mass: 0,11kg
• Specific heat capacity: 890J/kg*K
• Measuring ranges
temperature: 2x 0…325°C
Heating power: 0…450W
• Required for Operation
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase