Description and Specification for Lab Tenders
Astra Scientific Computerized Bench Top Cold Storage Trainer.
The trainer features a large refrigeration chamber. Two evaporators
allow for an investigation of the effect of different evaporator sizes
on the cold storage room climate and the icing. An electric defrost
heater and hot gas defrosting are available. The defrost process can be
performed as required using a defrost controller or at set intervals
using a defrost timer.
Two adjustable heat sources in the refrigeration chamber simulate the
cooling load. One of these heat sources generates water steam to
simulate the introduction of humidity into the refrigeration chamber.
The measured values can be read on digital displays. At the same time,
the measured values can also be transmitted directly to a PC via USB.
The data acquisition software is included. The data acquisition enables
e.g. the recording of the defrosting process over time and the online
representation of the climate in the refrigeration chamber in the h-x
diagram. The flow rate of the refrigerant is determined by means of the
pressure measurement.
FEATURES:
• Effect of the evaporator size and temperature on the climate in the refrigeration chamber
• Frosting and icing under different operating conditions
• Difference between latent and sensitive cooling load
• Different defrosting methods (electric heater, hot gas)
• Configuration of defrost controls such as defrost timer or defrost controller
SPECIFICATION:
• Compressor suitable capacity
Refrigeration capacity at -5/55°C: 999W
Power consumption: 565W
Latent cooling load: 2x 0…250W
Sensitive cooling load: 1x 0…200W, 1x 0…250W
• Receiver: 1,3L
• Refrigerant R134a/22/etc.
Filling volume: 1,3kg
CO2-equivalent: 0,8t
• Measuring ranges
Pressure: 2x 0…16bar, 1x 0…25bar
Temperature: 7x -50…150°C; 1x -25…125°C
Rel. humidity: 0…100%
Flow rate: 2…27L/h
• Required for operation
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase