Description and Specification for Lab Tenders
Astra Scientific Vapour Jet Refrigeration Trainer.
The Unlike standard compression refrigeration systems, vapour jet
refrigerating machines do not have a mechanical but a vapour jet
compressor. This makes it possible to use different heat sources for
cold production. Such sources could e.g. be solar energy or process
waste heat.
The system includes two refrigerant circuits: one circuit is used for
cold production (refrigeration cycle), the other circuit is used for the
generation of motive vapour (vapour cycle).
The vapour jet compressor compresses the refrigerant vapour and
transports it to the condenser. A transparent tank with a water-cooled
pipe coil serves as condenser.
In the refrigeration cycle some of the condensed refrigerant flows into
the evaporator connected to the intake side of the vapour jet
compressor. The evaporator is a so-called flooded evaporator where a
float valve keeps the filling level constant. The refrigerant absorbs
the ambient heat or the heat from the heater and evaporates. The
refrigerant vapour is aspirated by the vapour jet compressor and
compressed again.
In the vapour cycle a pump transports the other part of the condensate
into a vapour generator. An electrically heated tank with water jacket
evaporates the refrigerant. The generated refrigerant vapour drives the
vapour jet compressor.
All relevant measured values, such as temperature and pressures, are
measured and displayed in the experimental unit. The heater power at the
evaporator is adjustable. The cooling water flow rate at the condenser
is adjusted using a valve.
FEATURES:
• Understanding compression refrigeration systems based on the vapour jet method
• Clockwise and anticlockwise Rankine cycle
- energy balances
-
calculation of the coefficient of performance of the refrigeration
circuit
• Thermodynamic cycle in the log p-h diagram - operating behavior under load
SPECIFICATION:
• Vapour jet compressor
dmin convergent-divergent nozzle: approx. 1,7mm
dmin mixing jet: approx. 7mm
• Condenser
Tank: approx. 3,5L
Pipe coil area: approx. 0,17m2
• Evaporator
Tank: approx. 3,5L
Heater power: 4x 125W
• Vapour generator
Refrigerant tank: approx. 0,75L
Water jacket: approx. 9L
Heater power: 2kW
• Pump
Max. Flow rate: approx. 1,7L/min
Max. Head: approx. 70mWS
• Measuring ranges
Current: 0...2,5A
, Voltage: 0...230VAC
Temperature: 10x -20...200°C
, Pressure: 2x 0...10bar / 2x -1...1,5bar
Flow rate (cooling water): 6...75g/s
• Required for operation
230V, 50Hz, 1 phase
230V, 60Hz, 1 phase